9.3
KMS
9.3.1
Required steps to follow
Preparations for mounting
Make the following preparations for mounting:
1. Procure tools, auxiliary materials, measuring and test equipment.
2. Check all components for visible damage. Defective components
mustn't be mounted.
3. Ensure that dimensions and tolerances on the installation side are suita‐
ble for attachment (for details, see dimensional drawing).
4. Check whether all components, mounting surfaces and threads are
clean.
5. Ensure that mounting can be done in a dry and dust-free environment.
Mounting KMS
Notes on mounting
1.
To allow trouble-free servicing, make sure that the following aspects are
fulfilled after KSM has been mounted:
●
Connection points are easily accessible
●
Address selector switches are easily accessible
●
Diagnostic LED is visible
2.
Preferably mount the device to a conductive surface. If this is impossi‐
ble, later on connect the second connection point of equipment ground‐
ing conductor at the device to the equipment grounding system of the in‐
stallation.
3.
For the dimensions of the mounting holes, see the dimensional drawing
of the device.
4.
Data of the mounting screws:
Devices of cooling type "A":
●
Thread: M6
●
Tightening torque: 6 Nm
●
Head diameter: < 11 mm
Devices of cooling type "B":
●
Thread: M5
●
Tightening torque: 6 Nm
Cold plate
Devices of cooling type "B" are mounted on a cold plate.
Required cold plate properties:
See
chapter 9.1.3 "Cold plate" on page 251
Bosch Rexroth AG
DOK-INDRV*-KCU02+KSM02-PR03-EN-P
254/337
Rexroth IndraDrive Mi Drive Systems with KCU02 KSM02, KMS02/03, KMV03, KNK03
Mounting and installation