RHS0014 terminal connector
Terminal Connector RHS0014
Each line of drives must be terminated at the last connection point X103.2,
using terminal connector RHS0014 (parts number: R911335793). The termi‐
nal connector is not coded.
C
Protective cap
M12
4-pin socket, D-coded; the pins are internally connected to the
contacts for Multi-Ethernet communication (Tx+, Tx-, Rx+, Rx-);
the connection point can be used for the drive system Engi‐
neering
Fig. 5-29:
Terminal Connector RHS0014
Tab. 5-27:
Internal M12 Socket Wiring
If it is difficult to access the M12 socket in your drive system:
Connect a cable (e.g. RKB0043) to the M12 socket and position
the end of the cable at an easily accessible point.
Bosch Rexroth AG
DOK-INDRV*-KCU02+KSM02-PR03-EN-P
120/337
Rexroth IndraDrive Mi Drive Systems with KCU02 KSM02, KMS02/03, KMV03, KNK03
Technical data of the components
LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01