14.4
Sizing mains filters (drive system)
The data are not binding. Further criteria are relevant for sizing
mains filters (mains voltage, mains current, mains frequency,
ambient temperature, harmonics on the mains voltage, EMC limit
value class, PWM of the drives …).
Therefore, check the determined values using the up-to-date
specifications in the corresponding product documentation, and
observe the Project Planning Manual "Rexroth IndraDrive Drive
Systems with HMV01/02 HMS01/02, HMD01, HCS02/03"
(R911309636).
An Excel-based tool is available for sizing mains filters. If
required,
please
ask
our
sales
representative
("FAQ_EMC_mains_filter_application_tool_EN").
Drive system
In the drive system described below, the components IndraDrive M (HMS,
HMD) or IndraDrive C/Cs (HCS) are operated together with IndraDrive Mi
(KCU, KSM, KMS) components.
IndraDrive Mi Drive Systems with KCU02, KSM02,
KMS02/03, KMV03, KNK03, KLC03
375/407
Appendix