6.8.4
X54.1, X54.2; DC bus
View
Connection Function
L+
DC bus positive pole
PE
L-
DC bus negative pole
Tab. 6-93:
Pin assignment
Mechanical data
Screw terminal (connector)
Unit
max.
Connection cable
Stranded wire
mm
2
6
AWG
8
Stripped length
mm
10
Tightening torque
Nm
0.8
Tab. 6-94:
Mechanical data
Electrical data
Screw terminal (connector)
Unit
Value
Occurring current load and minimum required
connection cross section
A
See technical data (I
L_cont
, I
L_max
and A
LN
)
Occurring voltage load
V
See technical data (U
LN
)
Tab. 6-95:
Electrical data
Cables
Description
Value
Order type
(KMV03 ↔ KLC03)
(KLC03 ↔ KLC03)
Maximum allowed length
tbd m
Tab. 6-96:
Cables
IndraDrive Mi Drive Systems with KCU02, KSM02,
KMS02/03, KMV03, KNK03, KLC03
215/407
Connection points
R911335703_Edition 04 Bosch Rexroth AG