Description
Symbol
Unit
HCS01.1E
-W0005-
_-03
HCS01.1E
-W0008-
_-03
HCS01.1E
-W0018-
_-03
HCS01.1E
-W0028-
_-03
HCS01.1E
-W0054-
_-03
Input capacitance
C
N3
mF
0.04
0.06
Rated power consumption control
voltage input at U
N3
4)
P
N3
W
27
28
34
45
Last modification: 2012-01-23
1) 2) 3)
Observe supply voltage for motor holding brakes
4)
See information on "Rated power consumption control voltage
input at U
N3
"
Tab. 7-41:
HCS - Control voltage supply data
Rated power consumption control voltage input at U
N3
Including control section, plus safety option
Overvoltage
Overvoltage greater than 33 V has to be discharged by means of
the appropriate electrical equipment of the machine or installation.
This includes:
●
24V power supply units that reduce incoming overvoltage to
the allowed value.
●
Overvoltage limiters at the control cabinet input that limit ex‐
isting overvoltage to the allowed value. This, too, applies to
long 24V lines that have been run in parallel to power cables
and mains cables and can absorb overvoltage by inductive
or capacitive coupling.
7.3.2
Mains voltage
Mains voltage supply data
Description
Symbol
Unit
HCS01.1E
-W0003-
_-02
HCS01.1E
-W0006-
_-02
HCS01.1E
-W0009-
_-02
HCS01.1E
-W0013-
_-02
HCS01.1E
-W0018-
_-02
Mains frequency
f
LN
Hz
50...60
Mains frequency tolerance
Hz
± 2
Maximum allowed mains frequen‐
cy change
Δf
LN
/Δt
Hz/s
2
Rotary field condition
None
Short circuit current rating
SCCR
A rms
42000
Nominal mains voltage
U
LN_nenn
V
3 AC 230
Single-phase mains voltage
U
LN
V
110...230
Three-phase mains voltage at TN-
S, TN-C, TT mains
U
LN
V
110...230
Last modification: 2012-06-28
DOK-INDRV*-HCS01******-PR05-EN-P
Bosch Rexroth AG
233/341
Rexroth IndraDrive CsDrive Systems with HCS01
Technical data of the components