7.1.10
Analog Output
Data
Unit
min
Typ.
max
Output voltage
V
-10
+10
Output load, ohmic
kΩ
2
Output load, capacitive
nF
100
Resolution
mV/incr
24
Conversion time (incl. response
time)
µs
750
250
1)
Output clock
Position controller clock
Precision (in relation to the measur‐
ing range)
±0.5% with load ≥ 10 kΩ
±1% with load ≥ 2 kΩ
Short circuit protection
Present
Overload protection
Present
1)
Applies to optional I/O extension DA
Tab. 7-38:
Analog Output
Bosch Rexroth AG
DOK-INDRV*-HCS01******-PR05-EN-P
228/341
Rexroth IndraDrive CsDrive Systems with HCS01
Technical data of the components