Required Adaptations after successful Installation
Mount Directory
The "mnt" mount directory is configured on C:\mnt ex works. As on IndraCon‐
trol VEP **.4 devices with Windows Embedded the interface is installed on the
D:\ application partition, the path for the mount directory has to be adapted
correspondingly. Modify the path as follows:
1. Move the "C:\mnt" directory to "D:\mnt"
2. Open the "D:\Program Files\Rexroth\IndraWorks\mtx\bin\export.us" file
and change the integrated path from "C:\mnt" to "D:\mnt". Then save the
file and close the file.
3. Reload the "export.us" file. For this, right-click on the NFS server icon in
the toolbar. Then select "Reload export.us".
Fig.9-32:
Execute Reload "export.us"
ENI Server
The path of the ENI server is preconfigured on "C:\ENI". The path also has to
be changed to "D:\ENI", similar to the mount directory. Modify the path as fol‐
lows:
1. Right-click on the ENI server icon in the taskbar. Then select "ENI Con‐
trol...".