The display identification of a VDP 92.3 is only active once after
switching on the VPB40.3. That means that if a VDP 92.3 is plugged
and then removed or a VDP 92.3 is connected when starting the
control cabinet PC, only a VDP 92.3 with the same resolution can
be connected again. Thus, it is ensured that the screen output on
the connected VDP 92.3 is executed automatically without switch‐
ing the screen output to the VDP using the keyboard.
XVID Assignment and XSER Assignment
All connections of the XVID and XSER interface are assigned.
Fig.6-8:
RJ45 female connector for the XVID and XSER interfaces
For information on the cable lengths related to the display resolution, please
refer to
chapter 11.2 "Accessories" on page 47
.
XVID and XSER Markings
The CDI interfaces are color-coded on the device:
CDI interface, data (XSER)
Violet
CDI interface, screen (XVID)
Black
Fig.6-9:
Colored marking on the CDI interfaces
6.2
Connector Panel of the Profibus Interface
Fig.6-10:
Connector panel of the Profibus interface
Project Planning Manual | Rexroth IndraControl VDP 92.3
Electric Drives
and Controls
| Bosch Rexroth AG
27/52
Interfaces