When installing CDI cables with a diameter of 7.4 mm observe the
bending radius:
●
Radius (when bended once during installation): 4 × cable diame-
ter
●
Minimum bending radius (when moved permanently): 8 × cable
diameter
●
Optimum bending radius (when moved permanently): 12.5 × ca-
ble diameter
Breakdown of the operation due to mechanical forces which impact
the CDI cables.
Avoid mechanical stress (tensile, compressive, torsional and lateral
forces) caused by connectors to the RJ45 female connector.
Breakdown of the operation due to changed CDI cables.
To be able to clearly identify the cables, label the cables, e.g. with a
cable marker or clips.
The maximum cable length depends on the display resolution:
●
Up to 50 meters: 1920 × 1080 pixels (only VDP 21.3)
●
Up to 70 meters: 1366 × 768 pixels (only VDP 15.3 and VDP 18.3)
Longer cables can be used when using a Y-repeater, see also ope-
rating instruction of the Y-repeater, part number
.
Screen output interference due to VDP device exchange during run-
ning operation if the resolution of the exchanged device is different.
The display resolution is detected only once after switching on the
control cabinet PC. Consequently, if a VDP is plugged and then re-
moved or if a VDP is connected when starting the control cabinet
PC, only a VDP with the same resolution can be connected again.
Thus, it is ensured that the screen output on the connected and dis-
connected VDP is executed automatically without switching the
screen output to the VDP using the keyboard.
Malfunctions caused by using inappropriate cables.
Use only cables listed in
chapter 5 "Spare Parts, Accessories and
.
Bosch Rexroth AG
Assembly, Disassembly and Electrical Installation
VDP 15.3, 18.3, 21.3 Multitouch
22/37