10.1.3 Bosch Design
346 mm (VDP 15.3), 478 mm (VDP 21.3)
420 mm (VDP 15.3), 552 mm (VDP 21.3)
35
43
273
mm (VDP 15.3), 348
mm
(VDP
21.3)
195
mm (VDP 15.3),
270
mm (VDP 21.3)
1
8
56
37
37
①
Field of vision of the display
Fig. 10-3: Housing dimensions of the operating display VDP 15.3/VDP 21.3 in millimetres,
Bosch design
10.2 Installation Notes
●
Provide a space of 50 mm on all sides of the device for sufficient cooling and
cable routing.
●
The LED displays on the connector must not be covered.
●
Lay all cable in loops. Use strain reliefs for all cables.
●
Only install the operating display vertically, with a max. deviation of ±45°,
measured from the vertical.
●
Do not lay the CDI cables in parallel to the motor cables or other noise sour-
ces as otherwise the CDI connection may be disturbed. Keep as much dis-
tance as possible to noise sources.
10.3 Assembly
Assemble the operating display as follows:
VDP 15.3, 18.3, 21.3 Multitouch
Bosch Rexroth AG
Assembly, Disassembly and Electrical Installation
DOK-SUPPL*-VDPXX.3MTBU-IT02-EN-P
17/37