10.3.2
Switching Times without Devices on the USB Connections
Switching condition
Switching time in standard
USB mode
Switching time in extended
USB mode
Switching to an other oper‐
ator terminal
Up to 5 seconds.
Up to 10 seconds.
Fig.10-3:
Switching times without devices connected to the USB connections
10.3.3
Switching Times with Devices on the USB Connections
Switching condition
Switching time in standard
USB mode
Switching time in extended
USB mode
Switching to an operator
terminal to which only al‐
ready known USB devices
are connected on the same
USB port.
Up to 5 seconds.
Up to 10 seconds.
Switching to an operator
terminal to which already a
new USB device has been
connected.
Up to 30 seconds.
(time until the USB device
is correctly installed by
Windows)
Up to 30 seconds.
(time until the USB device is
correctly installed by Win‐
dows)
Fig.10-4:
Switching times with devices connected to the USB connections
Incorrect operation at the VDP possible when
switching the Y-repeater.
NOTICE
The devices connected to the XUSBx USB connections can be operated up to
three seconds at the disabled VDP. The key operation and touch operation of
the deselected VDP is immediately disabled.
10.4
Interfaces on the Y-Repeater
10.4.1
View on the Connector Panel
The connections are located at the front panel of the Y-repeater.
DOK-SUPPL*-VDP*08.3***-PR02-EN-P
Rexroth IndraControl VDP 08.3/40.3 Operator Terminal
Bosch Rexroth AG
61/81
Y-Repeater