Standard
Meaning
EN 60 664-1
Overvoltage category II
EN 61 131-2
Requirements regarding the 24 V outputs
EN 61 131-2
Requirements on the 24 V power supply
ISO 13 850
Machine safety, EMERGENCY STOP devices
EN 60 529
Degrees of protection (including housings and installation
compartments)
EN 60 068-2-6
Vibration test
EN 60 068-2-27
Shock test
EN 60 721-3-1 and
EN 60 721-3-3
Climatic class
Fig.4-4:
Used standards
Emergency stop button - standards
The emergency stop button is disclosed by the manufacturer as safety com‐
ponent according to machinery directive 2006/42/EC (annex V-10, emergency
stop devices). The compliance with the directive is proven by adherence to the
following European standards:
●
IEC 60204-1 (safety of machinery – electrical equipment of machines)
●
IEC 60947-5-1/5 (requirements for control circuit devices, requirements
for emergency stop devices)
●
ISO 13850 (safety of machinery - emergency stop - principles for design)
According to DIN EN ISO13849-1 the B10d value is:
Mechanics
Electrics
B10d = 250 000
exclusion of failure at < 6050 switching cy‐
cles
B10d = 5 000 000
exclusion of failure at < 6050 switching cy‐
cles
Fig.4-5:
Emergency stop button, B10 d value, service life
4.4.2
CE Marking
Declaration of Conformity
The electronic products described in the project planning manual comply with
the requirements and goals of the following EC guideline and with the agreed
European standards:
EMC guideline 2004/108/EC
The electronic products described in the project planning manual comply with
the requirements on the operation within the industrial environment:
DOK-SUPPL*-VDP*08.3***-PR02-EN-P
Rexroth IndraControl VDP 08.3/40.3 Operator Terminal
Bosch Rexroth AG
23/81
Technical Data