8
-4
Bosch Rexroth AG
| Electric Drives and Controls
Rexroth IndraControl VCP 08
|
R911310379
/
02
Maintenance and Installation
Use the following procedure to connect the device to the supply volt-
age:
1. Remove approx. 30 mm (1.181") off the outer cable sheath and ap-
prox. 5 mm (0.197") off the wires.
Fig. 8-3:
Preparing the cable
2. Fit the wires with wire end ferrules and connect the wires to the con-
nector.
Fig. 8-4:
Connecting the female connector strip
If shielded connecting cables are used in the supply voltage area, the
shield should be connected to pin 1.