4.4.3
UL ratings
Introduction
This chapter contains:
●
Limit values for use within the scope of CSA / UL
●
Applied standards (CE conformity, UL listing)
Inverter
Ambient and operating conditions - UL ratings
Description
Symbol
Unit
HMU05.1N-
F0140-0350-
N-A4-D7-P
HMU05.1N-
F0170-0430-
N-A4-D7-P
HMU05.1N-
F0220-0510-
N-A4-D7-P
HMU05.1N-
F0270-0660-
N-A4-D7-P
Short circuit current rating
SCCR
A rms
85000
Rated input voltage, power
1)
U
LN_nenn
V
DC 450...750
Rated input current
I
LN
A
242.0
291.0
373.0
467.0
Output voltage
U
out
V
3 x AC 0...500
Output current
I
out
A
254.0
306.0
392.0
490.0
Last modification: 2015-12-03
1)
Mains input L1, L2, L3 (for HMV and HCS only); For use on a
solidly grounded wye source only.
Tab. 4-11:
HMU – ambient and operating conditions – UL ratings
Ambient and operating conditions - UL ratings
Description
Symbol
Unit
HMU05.1N-
F0340-0820-
N-A4-D7-P
HMU05.1N-
F0430-1040-
N-A4-D7-P
HMU05.1N-
F0540-1300-
N-A4-D7-P
HMU05.1N-
F0680-1690-
N-A4-D7-P
Planned
Short circuit current rating
SCCR
A rms
85000
Rated input voltage, power
1)
U
LN_nenn
V
DC 450...750
Rated input current
I
LN
A
587.0
734.0
954.0
tbd
Output voltage
U
out
V
3 x AC 0...500
Output current
I
out
A
616.0
771.0
1002.0
tbd
Last modification: 2015-12-03
1)
Mains input L1, L2, L3 (for HMV and HCS only); For use on a
solidly grounded wye source only.
Tab. 4-12:
HMU – ambient and operating conditions – UL ratings
DOK-INDRV*-HXX05******-PR02-EN-P
Bosch Rexroth AG
79/407
Rexroth IndraDrive ML Drive Systems with HMU05
Combining the individual components