Stopping procedure
Stopping with the main switch
1. Turn the main cut-off switch (A) to the "OFF" po‐
sition.
●
The signal light (B) will switch off.
●
Machine operation stops and the electricity sup‐
ply to the electrical panel is interrupted.
●
The terminals for the connection to the mains re‐
main live.
Stopping with the key-operated switch
This stop mode is reserved for authorised personnel.
1. Insert the key into the selector switch (C).
2. Turn the selector switch to the "Service" posi‐
tion.
●
Operation of the main pump stops.
●
The electrical panel on the machine remains
live.
Remote-controlled stopping
Remote-controlled stopping must be performed using
the owner’s operating terminal, via the "ENABLE" con‐
nection.
●
Operation of the main pump stops.
●
The electrical panel on the machine remains
live.
Tab. 8-102:
Stopping procedure
Stopping in emergency conditions
To stop the appliance in the event of imminent danger (emergency stop), turn
the main cut-off switch (A) to the "OFF" position.
Eliminate the cause of the emergency stop before re-starting the machine.
DOK-INDRV*-HXX05******-PR02-EN-P
Bosch Rexroth AG
309/407
Rexroth IndraDrive ML Drive Systems with HMU05
Cables, accessories, additional components