![Bosch Rexroth HMU05.1N Series Project Planning Manual Download Page 280](http://html.mh-extra.com/html/bosch/rexroth-hmu05-1n-series/rexroth-hmu05-1n-series_project-planning-manual_44851280.webp)
SF1 switch
Use
Activate or deactivate "Auto-ZKS" (auto DC bus short-circuit) function.
With the "Auto-ZKS" (auto DC bus short-circuit) function, the device automati‐
cally executes a DC bus short circuit (ZKS) if the external 24 V control volt‐
age supply fails.
The "Auto-ZKS" (auto DC bus short-circuit) function is deactivated by default.
Type
DIP; 2-pin
Fig. 8-72:
SF1 switch
The switch sits underneath a cover. The cover can be removed using a
screwdriver.
Function
Switch 1
Switch 2
Auto-ZKS (auto DC bus short-circuit) activated?
ON
ON
–
ON
OFF
✓
OFF
ON
✓
OFF
OFF
✓
ON
Move switch down to the lowermost position
OFF
Move switch up to the topmost position
Sliding force 8 N
Tab. 8-84:
Function
Bosch Rexroth AG
DOK-INDRV*-HXX05******-PR02-EN-P
278/407
Rexroth IndraDrive ML Drive Systems with HMU05
Cables, accessories, additional components