Pressure Switch |
HED 8
5/16
RE 50061, edition: 2016-09,
Bosch Rexroth AG
Technical data
(For applications outside these parameters, please consult us!)
Electrical
Electrical
connection
▶ with “K14” connector
EN 175301-803, 3-pole + PE
▶ with “K35” connector
IEC 61076-2-101, M12 x 1, A-coding, 4-pole
Protection class accord-
ing to DIN EN 60529
▶ with “K14” connector
IP 65 with mating connector fitted and screwed in place
▶ with “K35” connector
IP 67 with mating connector fitted and screwed in place
Maximum switching frequency
1/h
7200
Switching accuracy (repetition accuracy)
< ± 1% of the set pressure
Switches
according to VDE 0630-1/DIN EN 61058-1
Transition resistance
mΩ
< 50
Insulation coordination
Overvoltage category 3
Contamination
Degree of contamination 3
Bounce time
▶ ON
ms
< 5
▶ OFF
ms
< 5
Utility model according to
IEC 60947
Minimum current
mA
1.0 with 24 V DC
DC-12
Maximum current
▶ with “K14” connector
A 0.5 at 50 V DC, inductive
0.2 at 125 V DC, inductive
0.1 at 250 V DC, inductive
2.0 at 250 V AC
DC-22
DC-22
DC-22
AC-12
▶ with “K35” connector
A 0.5 with 48 V DC, inductive
2.0 with 48 V DC, ohmic load
DC-22
AC-12
Switching power
Switching cycles
Voltage
U
in V
Ohmic load max. in A
Inductive load, max. in A
with “K14” connector
2 million
250, AC
2 A for 2 million circuits (AC-12)
0,5 A, cos. ϕ = 0,6 for 2 mil. circuits (AC-22)
With “K14” and “K35” connectors
2 million
24, DC
2 A for 2 million circuits (DC-12)
0.5 A for 2 million circuits
3)
5 million
24, DC
5.0 mA for 5 million circuits (DC-12)
–
1)
Direction of rotation:
– clockwise → set pressure increase
– anti-clockwise → set pressure decrease
2)
The cleanliness classes specified for the components must be
adhered to in hydraulic systems. Effective filtration prevents faults
and at the same time increases the life cycle of the components.
For the selection of the filters see www.boschrexroth.com/filter.
3)
Value does not comply with any utility category according to
IEC 60947