Rexroth EcoDrive Cs
Ratings and Dimensions
3-1
DOK-ECODR3-DKC*CS*UL**-IB01-EN-P
3
Ratings and Dimensions
Description
Symbol
Unit
DKC**.3-004
DKC**.3-008
DKC**.3-012
DKC**.3-018
listing according UL-standard
(UL)
UL 508 C
listing according CSA-standard
(UL)
Canadian National Standard(s) C22.2 No. 14-05
UL files (UL)
E 227957
pollution degree (UL)
Use in a pollution degree 2 environment. The device is to be
installed in an enclosure that provides pollution degree 2.
maximum ambient temperature
with nominal data (UL)
T
amax
°C
40 °C
maximum ambient temperature
with reduced nominal data (UL)
T
amax_red
°C
55 °C
Weight
m
kg
1,8
2,1
Device height (UL)
1)
H
mm
182
Device depth (UL)
2)
T
mm
170
Device width (UL)
3)
B
mm
55
70
minimum distance on the top of
the device
4)
d
top
mm
50
minimum distance on the
bottom of the device
5)
d
bot
mm
50
rated control voltage input (UL)
6)
U
N3
V
24 ac
rated power consumption
control voltage input without
holding brake, without control
section at U
N3
= DC 24 V (UL)
7)
P
N3
W
n / a
n / a
n / a
n / a
short circuit current rating,
SCCR, symmetrical amperes
(UL)
8)
I
SCCR
A
rms
5000
rated input voltage, power (UL)
9)
V
200 – 230 ac
200 – 240 ac
tolerance rated input voltage
(UL)
%
n / a
n / a
n / a
n / a
input number of phases (UL)
3 (1)
3 (1)
3(1)
3
input frequency (UL)
f
LN
Hz
50 / 60 Hz
tolerance input frequency (UL)
Hz
n / a
n / a
n / a
n / a
maximum input current (UL)
10)
I
L_cont
A
1,1
1,3
2,2
3,1
branch circuit protection fuse
(UL)
11)
2
2
3
4
field wiring material (UL)
12)
Use 60/75 °C copper wire only, use class 1 wire only or equivalent
required wire size according UL
508 A (internal wiring); at I
L_cont
(UL)
13)
A
LN
AWG 14
maximum output voltage (UL)
U
out
V
84
92
106
116
output number of phases (UL)
3
maximum output current (UL)
I
out_max
A
1
1,6
2,5
4,3
maximum output frequency
(UL)
14)
f
out
Hz
333,3
300
Courtesy
of
CMA/Flodyne/Hydradyne
▪
Motion
Control
▪
Hydraulic
▪
Pneumatic
▪
Electrical
▪
Mechanical
▪
(800)
426-5480
▪