56/60 Troubleshooting
Bosch Rexroth AG
, A10VO, A10VSO Series 31, RE 92701-01-B/04.2018
Table 14: Axial piston unit malfunction table
Malfunction
Possible cause
Remedy
Excessively high temperature of
hydraulic fluid and housing
Excessively high inlet temperature at the axial
piston unit
Machine/system manufacturer: inspect system,
e.g. malfunction in the cooler, insufficient
hydraulic fluid in the reservoir
Wrong setting or malfunction in the pressure
relief and pressure control valves (e.g. high-
pressure relief valve, pressure cut-off, pressure
controller)
Optimize the adjustment of the pressure
limitation and pressure control valves of the
axial piston unit and the pressure safeguarding
in the hydraulic system
Contact Bosch Rexroth Service
Contact machine/system manufacturer
Axial piston unit worn
Replace axial piston unit; contact
Bosch Rexroth Service