26/48 Installation
Bosch Rexroth AG
, 4WS2EM 10...XL..., RE29583-XL-B/09.20
WARNING
Explosion hazard!
The servo amplifier is
not
approved according to the EU Explosion Protection
Directive 2014/34/EU. The use of the servo amplifier in an explosive atmosphere
may cause an explosion!
▶
Only use the servo amplifier outside the explosive environment.
Table 12: Servo amplifier in modular design
Type
Documentation to be carried
Servo amplifier in modular design
VT11021
Data sheet 29743
Table 13: Mating connector
Material number
Mating connector
R901044595
The addresses of our responsible sales organizations can be found on the Internet at
www.boschrexroth.com
and in appendix 16.1 "List of addresses".
7.7 Assembling the valve
7.7.1 Flushing the system
WARNING
Faulty mounting!
Fastening the flushing plate using mounting screws of reduced stability may cause
the flushing plate to become loose. Consequently, hydraulic fluid may leak and lead
to personal injury and/or damage to property.
▶
Completely assemble the flushing plate according to the assembly specifications
using suitable assembly aids.
▶
Observe the tightening torques, screw stabilities and the minimum length of the
mounting screws.
▶
Always fasten the flushing plate with all 4 mounting screws.
▶
Only assemble the flushing plate using the mounting screws intended for that
purpose and included in the scope of delivery.
Before installing the valve into a device or system, the system must be flushed.
Only then is the unobjectionable functioning of the valve guaranteed. With an
external pilot oil supply, make sure that it is flushed, as well. Also observe the
operating instructions of the device and/or system into which the valve is installed.
Servo amplifier (external)
Mating connector
Ordering address for
accessories and valves