8 Parameter list
Par� no�
Function
Default setting
Description
Customer settings for
IMSc TTL10 µm
P01
Counting direction
0
forwards
P02
Display measurement unit
0
mm
0
P03
Decimal point
1
1 decimal place
2
P04
Reserve
-
-
P05
Keyboard lock
0
deactivated
P06
Edge evaluation
0
1 edge
2
P07
Measuring system selection
0
incremental
0
P08
Multiplication factor
01.00000
01.00000
P09
Reference value
000000.0
P10
Tool offset
000000.0
P11
Saw blade
0000.0
P12
Reserve
-
-
P13
Reserve
-
-
P14
Reserve
-
-
P15
Reserve
-
-
P16
Default init
0
not active
P17
Function ext. input 1
0
not active
P18
Function ext. input 2
0
not active
P19
Trigger external input 1
0
level-sensitive
P20
Display mode
0
standard
0
P21
Reserve
-
-
P22
Reserve
-
-
P23
Reserve
-
-
P24
Reserve
-
-
P25
Reserve
-
-
P99
Software version
-
-
Table 4:
Parameter list
12/18
Bosch Rexroth AG
IMScompact position display | R320103179/2019-12