57.6.3 Logging status button
The
Logging Status
window displays the status of the
Logging Viewer
.
57.6.4 Blocks
When the current view is the
Historical
view (see section
57.6.2.3) and the number of historical events is greater
than 10000, the
Logging Server
delivers the events in
blocks to the
Logging Viewer
.
•
If a next block is available, the
Next Block
button is
enabled. The next block contains events that are
newer than the events that are currently displayed.
•
If a previous block is available, the
Prev Block
button
is enabled. The previous block contains events that
are older than the events that are currently displayed.
Message:
The Logging Server and Viewer are OK.
Description:
The
Logging Server
and
Logging Viewer
operate
correctly.
Recommended action:
----
Message:
Logging Server has no connection with
<system>
Description:
There is no connection with the specified system.
Recommended action:
Make sure that the specified system is running and
that the specified system has an Ethernet connection
with the
Logging Server
.
Message:
The Logging Viewer has lost contact with the
Logging Server
Description:
There is no connection with the
Logging Server
.
Recommended action:
Make sure that the
Logging Server
is running and that
the
Logging Server
has an Ethernet connection with
the
Logging Viewer
.
Message:
The Logging Server options are changed. Restart the
Logging Server to use the changed settings.
Description:
The configuration settings of the
Logging Server
were
changed. The changed settings are not used until the
Logging Server
is restarted.
Recommended action:
Restart the
Logging Server
to use the new settings.
Message:
The Logging Server database has reached its critical
size. Please decrease the logging expiration periods.
Description:
The database has reached its critical size.
Recommended action:
Enable and decrease the logging expiration periods to
move events to the overflow files (see section 56.7.3)
or flush the database (see section 56.7.4.4).
Message:
The Logging Server overflow files have reached their
critical size. Please clear or delete the overflow files.
Description:
One or more overflow files have reached the critical
size.
Recommended action:
The overflow files are comma separated value (*.
csv
)
files. They can be opened in an editor (e.g. Windows
Wordpad, Microsoft® Excel). When an overflow file
reaches its critical size, use an editor to delete data
from the overflow file and decrease its size.