Bosch Security Systems | 2011-02
Praesideo 3.5
| Installation and User Instructions | 3 | Control Equipment
en
| 100
5.6.7
Set monitoring options
The
Monitoring
submenu is used to set which signal is
sent to the monitoring loudspeaker or headphones. It
can be one of the audio inputs, one of the audio outputs
or no signal at all. Furthermore, the screen provides
level meters for a visual identification of the actual
signal strength.
5.6.8
Set date and time
The
Date & Time
menu item is used to change the date
and time displayed by the network controller.
5.6.9
Setup TCP/IP
The
TCP/IP Setup
submenu is used to set the TCP/IP
parameters of the network controller.
table 5.12: Monitoring submenu
Menu item
Option
Value 1
Value 2
Description
1 Monitoring
Source:
-
Input
n
Input nr:
1
to
4
Volume:
-31
to
0 dB
The signal from audio input n is
available on the monitoring
loudspeaker or headphones output.
-
Output
n
Output nr:
1
to
4
Volume:
-31
to
0 dB
The signal from audio output n is
available on the monitoring
loudspeaker or headphones output.
-
Off
*
The monitoring loudspeaker or
headphones output is off during
normal operation.
table 5.13: Date & Time menu item
Menu item
Option
Value 1
Value 2
Description
2A Date & Time
Date:
2000-01-01
to
2037-12-31
Time
00:00
to
23.59
The date is displayed in the
yyyy-mm-dd format, the time is
displayed in the hh:mm format.
table 5.14: TCP/IP Setup submenu
Menu item
Value
Description
2Ba Address
e.g.
192.168.000.015
IP address of the network controller.
2Bb Subnet Mask
e.g.
255.255.255.000
Subnet mask for the network controller.
2Bc Def. Gateway
e.g.
192.168.000.050
Default gateway for the network controller.