Before connecting the unit, check whether the local connection 

conditions (type of gas) are compatible with the unit’s setting. 

Observe any special conditions imposed by local suppliers 

(utilities). The specifications of this cooktop are stated on the 

data label located on the bottom of the cooktop base.
A duplicate data label is supplied for adhesion to an accessible 

location near the hotplate if the data label on the base of the 

hotplate cannot be accessed when the hotplate is installed.

Clearances

A range hood fitted above the top must be installed according 

to the installation instructions for the range hood. A minimum 

distance of 650 mm is required for a range hood and 750 mm 

for an exhaust fan.
Any adjoining wall surface situated within 200 mm from the 

edge of any hob burner must be a suitable non-combustible 

material for a height of 150 mm for the entire length of the hob. 

Any combustible construction above the hotplate must be at 

least 650 mm above the top of the burner and no construction 

shall be within 450 mm above the top of the burner.

A minimum depth of 50 mm from the top of the worktop 

surface must be provided for the appliance. 
If the base of the hotplate can be touched, a protecting shield 

must be fitted.

The shield must be at least 10 mm from the lowest part of the 

hotplate and must be capable of withstanding the appliance 

temperatures. Minimum thickness of benchtop is 30 mm.

The shield material must be mdf or similar with minimum 

thickness of 12 mm.

PP

PP

PP

PLQPP

PLQPP

PLQPP

PP

PLQPP

PP

PLQPP

PP

PLQPP

PLQPP

PP

PLQPP

PP

PP

PP

PP

PP

PLQPP

PP

PLQPP

PLQPP

PP

PLQPP

PP

PP

PLQ

PLQ

Summary of Contents for PCD345DA

Page 1: ...USER INSTRUCTIONS INSTALLATION INSTRUCTIONS MAINTENANCE INSTRUCTIONS This cooktop is for use with Natural Gas and Universal LPG Leave this instructions with the owner PCD345DA ...

Page 2: ...entilation Do not obstruct the flow of combustion and ventilation air Cabinets installed above the gas cooktop must have a minimum clearance of 650 mm 24 The gas pressure regulator supplied with the appliance must be installed in line with the gas pipe N G only For pressure testing in excess of 3 5 kPa 1 2 psig the appliance and its individual shutoff valve must be disconnected from the gas supply...

Page 3: ...n instructions Local Gas Fitting Regulations Municipal Building Codes Refer to AS NZS 5601 1 for Gas Installations S A A Wiring Code Local Electrical Regulations Any other statutory regulations Preparing to install Refer to AS NZS 5601 1 for piping size details These built in cooktops are intended to be inserted in a benchtop cutout Only an officially authorised technician should connect the appli...

Page 4: ...joining wall surface situated within 200 mm from the edge of any hob burner must be a suitable non combustible material for a height of 150 mm for the entire length of the hob Any combustible construction above the hotplate must be at least 650 mm above the top of the burner and no construction shall be within 450 mm above the top of the burner A minimum depth of 50 mm from the top of the worktop ...

Page 5: ...ing lead which must be fixed to the kitchen unit to prevent it from coming into contact with hot parts of the cooktop or an oven installed underneath and remain accessible after installation of the cooktop When making this connection make sure that the lead cannot come into contact with hot parts of the cooktop This appliance must be earthed When connecting the cooktop ensure that the earth wire i...

Page 6: ...and must comply with current regulations and the conditions laid down by the local gas company Request change over injectors from our customer service deparment refer injector chart below for sizes Before conversion the cooktop must be disconnected from the electricity and gas valves must be turned to the OFF position Changing the nozzles of the burners on the cooktop 1 Remove the pan supports bur...

Page 7: ...parks are produced on all burners The flame ignites 2 Release the control knob 3 Turn the control knob to the required setting If it does not come on turn the control knob to the off setting and repeat the steps above This time press and hold the control knob for longer up to 10 seconds Risk of deflagration If after 15 seconds the flame does not ignite switch off the burner and open a nearby windo...

Page 8: ...ns The chart below gives the correct pan usage for each burner Precautions for use The following advice is intended to help you save energy and prevent pan damage Setting Û Control off Large flame Maximum capacity or aperture and elec tricity on Economy flame Minimum capacity or aperture Burner Very high High Medium Low Rapid burner Escalopes steaks ome lettes frying Rice white sauce ragout Steami...

Page 9: ...d Before calling the Technical Assistance Service bear in mind the following advice Any of the following are considered to be abnormal operation and may require servicing Yellow tipping of the cooktop burner flame Sooting up of cooking utensils Burners not lighting properly Gas valves which are difficult to turn in case the appliance fails to operate correctly contact the authorised service provid...

Page 10: ...10 Wiring diagram A Switch B Blue wire C Brown wire D Terminal E Ignition module ...

Page 11: ...B 9000941667 9000941667 Robert Bosch Hausgeräte GmbH Carl Wery Straße 34 81739 München Germany www bosch home com ...