Electrical connection
en-us
9
max. 2¾" (69 mm) + fitting/conduit 1" (25 mm)
min. 1" (25 mm) air clearance
approx. 12" (300 mm)
junction box
flexible conduit approx. 3 ft. (900 mm)
Power supply
All models must be connected with the included 39" (1 m) flexible conduit.
Models
240 V AC, 3-wire, 60 Hz system: cir-
cuit breaker
208 V AC, 3-wire, 60 Hz system: cir-
cuit breaker
NIT5060UC
30 A
30 A
NIT8060SUC
30 A
30 A
NIT8060UC
30 A
30 A
NITP060SUC
30 A
30 A
NITP060UC
30 A
30 A
NIT5660UC
40 A
40 A
NIT8660SUC
40 A
40 A
NIT8660UC
40 A
40 A
NITP660SUC
50 A
50 A
NITP660UC
50 A
50 A
NIT5460UC
30 A
30 A
5.2 Connecting electrical supply
WARNING
Before installing, turn power OFF at the service panel.
▶
Lock service panel to prevent power from being turned
ON accidentally.
Note: If the cooktop is installed and connected as speci-
fied here, it will be grounded in compliance with the Na-
tional Electrical Code.
1.
Install a suitable junction box (not furnished).
The branch-circuit breakers ampacity, the wire sizes
and the connections must conform to the requirements
of the National Electrical Code or Canadian Electrical
Code and all local codes and ordinances.
2.
Attach the flexible conduit to the junction box.