MIC IP starlight 7000i
Typical System Configurations | en
51
Bosch Security Systems
Installation Manual
2019-11 | 2.1 |
12.3
Typical IP Configuration with VJC-7000-90
Cat5e/Cat6e = 100 m max.
1
1
Figure
12.3: Basic configuration with VIDEOJET connect 7000
1 Ethernet (network) cable (Cat5e/Cat6 Shielded Twisted Pair (STP)) (user-supplied)
between a Bosch camera and the port labeled
PoE
on VIDEOJET connect 7000
2 Data-only IP cable (Cat5e/Cat6 Shielded Twisted Pair (STP)) to the head-end network
Note:
The cable to the head-end also can be fiber optic cable from one of the two SFP
slots.
3 Alarm input / output interface cables (user-supplied)
4 Alarm output cables (user-supplied)
5 120 / 230 VAC, 50/60 Hz
6 Audio input interface cable (user-supplied)
7 External washer pump (user-supplied)
8 Washer output, 2-conductor (user-supplied)
Note
: The total length of Cat5e/Cat6 Shielded Twisted Pair (STP) cable must be less than 100
m (328 ft) between the camera and the head-end system.