6
en | Safety
MIC IP fusion 9000i
2022-09 | 1.6 | F.01U.334.820
Installation Manual
Bosch Security Systems
1.4
Important Safety Instructions
When transporting, take extra care to protect the wiper and the camera window(s).
!
Caution!
Installation must be made by qualified personnel and conform to ANSI/NFPA 70 (the National
Electrical Code
®
(NEC)), Canadian Electrical Code, Part I (also called CE Code or CSA C22.1),
and all applicable local codes. Bosch Security Systems accepts no liability for any damages or
losses caused by incorrect or improper installation.
!
Warning!
INSTALL EXTERNAL INTERCONNECTING CABLES IN ACCORDANCE TO NEC, ANSI/NFPA70
(FOR US APPLICATION) AND CANADIAN ELECTRICAL CODE, PART I, CSA C22.1 (FOR CAN
APPLICATION) AND IN ACCORDANCE TO LOCAL COUNTRY CODES FOR ALL OTHER
COUNTRIES. BRANCH CIRCUIT PROTECTION INCORPORATING A 20 A, 2-POLE LISTED
CIRCUIT BREAKER OR BRANCH RATED FUSES ARE REQUIRED AS PART OF THE BUILDING
INSTALLATION. A READILY ACCESSIBLE 2-POLE DISCONNECT DEVICE WITH A CONTACT
SEPARATION OF AT LEAST 3 mm MUST BE INCORPORATED.
!
Warning!
ROUTING OF EXTERNAL WIRING MUST BE DONE THROUGH A PERMANENTLY EARTHED
METAL CONDUIT.
i
Notice!
Outdoor installation
For details about the proper configuration for installing your camera outdoors with surge and
lightning protection, refer to Best Practices for Outdoor Installation.
–
Ensure that the unit case is properly earthed. If the product is at risk of being struck by
lightning, ensure that earth bonding connections are made correctly to the mounting of
the base of the unit.
i
Notice!
Bosch recommends the use of surge/lightning suppression devices (sourced locally) to
protect network and power cables and the camera installation site. Refer to NFPA 780, Class
1 & 2, UL96A, or the equivalent code appropriate for your country/region, and to local
building codes. Refer also to the installation instructions of each device (midspan, camera,
and surge suppression device installed where the cable enters the building).
i
Notice!
Ancillary power (UPS) required
To meet the Mains Supply Voltage Dips and Short Interruptions requirements per EN 50130-4
Alarm Standard, ancillary equipment (for example, an Uninterruptible Power Supply (UPS)) is
necessary. The UPS must have a Transfer time between 2-6 ms and Backup Runtime of
greater than 5 seconds for the power level as specified on the product data sheet.
!
Warning!
THE CAMERA MUST BE MOUNTED DIRECTLY AND PERMANENTLY TO A NON-COMBUSTIBLE
SURFACE.