1 689 989 289
2014-12-04
|
Robert Bosch GmbH
Technical data | KTS 530 / 540 / 570 (KTS 5 Series) | 29
en
7.5
Power pack
Property
Value/Range
Input voltage
90 VAC — 264 VAC
Input frequency
47 Hz — 63 Hz
Output voltage
15 V
Operating temperature
0 °C — 40 °C
7.6
Bluetooth Class 1
Wireless connection
KTS 540 / 570 to PC/Laptop
Minimum range
Workshop environment in the open
space
30 meters
If the vehicle door or window is open
and the engine is still running in the ve-
hicle interior
10 meters
7.3.2
AC and effective value measurement
(CH1 and CH2)
*)
Property
Value/Range
Frequency range AC 10 Hz — 400 Hz (-3 dB)
Measurement range 200 mV — 30 V
AC precision at
100 Hz
EFF precision at ≤
100 Hz
±2 % of measurement value, additional
±0.5 % of measurement range
Resolution
100 µV — 100 mV
(depending on measuring range)
*)
The measuring ranges and types of measurement "U" and "I" are
peak-to-peak values. This results in the digital display field being
grayed out as soon as the defined measuring range has been
exceeded for a short time (Overload).
7.3.3
Resistance measurement (CH1)
Property
Value/Range
Measurement range 100 Ω — 1 MΩ
Precision up to
200 KΩ
±0.75 % of measurement value
additional ±0.25 % of measurement range
Precision up to
1 MΩ
±2 % of reading
additional ±0.25 % of measurement range
Resolution
0.1 Ω — 1000 Ω
(depending on measuring range)
Input resistance
> 9 MΩ
7.3.4
Current measurement (CH1 and CH2)
Sensor
Measurement range
Shunt (CH1 only)
±600 mA
30 A clamp (CH1 only)
±30 A
100 A clamp
±100 A
600 A clamp
±600 A
1000 A clamp (CH1 only)
±1000 A
7.3.5
Continuity tester (CH1)
Property
Value/Range
Measurement current
2 mA
Open circuit voltage
≤ 5 V
Continuity
< 10 Ω (with acoustic response)
7.3.6
Diode measurement (CH1)
Property
Value/Range
Measurement current
2 mA
Open circuit voltage
≤ 5 V
Maximum diode voltage
2 V
7.4
Oscilloscope specifications
Measuring channel 1 (CH1)
zero potential
Measuring channel 2 (CH2)
potential based
Input resistance > 900 kOhm.
Property
Value/Range
Measurement range
0 V — 60 VDC, 30 VAC, 42 VACpeak
Coupling
DC, AC,
DC(+) (only positive range is shown),
DC(-) (only negative range is shown).
Signal source
U, 30 A (CH1 only), 100 A, 600 A,
1000 A (CH1 only),
Diagnosis pins 1 to 15
(not pins 4, 5)
X-deflection
50 µs — 1 s
Trigger mode
Manual, Auto-Time, Auto-Level
Trigger source
CH1, CH2
Pretrigger time
0 % — 80 %
Frequency range
> 1 MHz (typical 5 MHz)
Memory depth per
channel
50 signal curves with 512 coordinates