7.10 No ice dispense
Fault:
Water will be supplied to ice tray and eis cubes can be even
produced. However produced ice cubes cannot be spelled out from
ice tray. Ice tray does not turn fully, so that spelling out of ice cubes is
not possible.
Cause:
An error at one of sensor in ice make causes this symptom, which
activates Ice tray (Full Ice Switch Sensor). The error code „Er Eu“will
be displayed on LED at Test program.
Remedial action:
Replace ice maker. If it is not corrected, check if the harness between
power module and sensors (1) is short or not. If there is no problem in
harness, check the power module.
7.11 Water under the appliance
Fault:
Water drops from water hose connections and collect under the
appliance
Cause:
If the water hose has been incorrectly cut, it can leak at the
connections to the water supply and the non-return valve. See
illustration: end of water hose cut off obliquely
1
1