Description of the ICP-COM-IF Module 

The ICP-COM-IF Module allows an isolated connection to be created between the MAP5000 (Interface 
Module DE) and an external communicator (for example the AT 2000) via the parallel S1 interface. The 
ICP-COM-IF Module offers: 

Notes for installation 

-

 

The ICP-COM-IF Module can be mounted on the hinged mounting plate or the mounting rails of the 
MAP control panel housing.  

-

 

A clearance of 15 mm is required on either side for subsequent wiring. Pull to disconnect the 
connectors. 

-

 

The enclosure of an external transmission unit has to be mounted side by side to the panel enclosure 
where the ICP-COM-IF module is mounted. 

 

Mounting 

1.

 

Hook the ICP-COM-IF  Module carrier plate into  the existing breadboard of the hinged mounting 
plate or onto the mounting rails. 

2.

 

Use the screw provided to secure the carrier plate to the bottom rail. 

 

Seven outputs:

  

The output signals from the MAP Interface Module DE 
control the ICP-COM-IF Module relays that provide isolated 
changeover contacts (R1 to R7) 

 

Two inputs:

  

The inputs ST and R (for the "Communicator fault" or 
"Negative confirmation" signals, for instance) can be 
controlled via the following: 
- isolated contacts 

- C points (isolated via optocouplers) 

Technical specifications 

Rated voltage 

+10 to +28 V DC 

Rated current 

67 mA at 28 V or 180 mA at 10 V 

Relay contacts rating 

3 A/120 V AC, 3 A/28 V DC 

Temperature range 

25 °C to +55 °C 

Weight 

198 g 

Dimensions (L x W x H) 

132 mm x 85 mm x 20 mm (5.2 inches x 3.3 
inches x 0.8 inches) 

 

Bosch Sicherheitssysteme GmbH 

Robert-Bosch-Ring 5 

85630 Grasbrunn 

Germany 

 

www.boschsecurity.com 

© Bosch Sicherheitssysteme GmbH, 2014 
 

V3  2014/11 

 

ICP-COM-IF 

EN 

 

Installation guide 

 

 

 

VdS class C G 111040 

EN 50131-2-6 Grade 3 

Jumper settings 

The inputs ST and R can be controlled via the following: 

 

isolated contacts

 

 

C points (isolated via optocouplers)

 

To control the inputs via external "isolated contacts" or "C points", the  jumpers  must be 
connected as follows: 

Input 

Jumper setting 

Description 

ST 

 

Control via isolated contact (factory default) 

 

Control via isolated contact (factory default) 

ST 

 

Control via C point 

 

Control via C point 

 

J1 

ST 

2  3 

J2 

ST 

2  3 

J3 

2  3 

J4 

J1 

ST 

2  3 

J2 

ST 

2  3 

J3 

2  3 

J4 

2  3 