en
Installation instructions
28
18 Installation instructions
The installation instructions contain instructions for
the gas connection and for the gas conversion's as-
sembly
.
Note:
For after-sales service only.
18.1 General information
Your appliance must only be converted from
one gas type to another by authorised per-
sonnel who have received appropriate train-
ing. The procedure must always be carried
out in accordance with the instructions in
this manual.
Incorrect connection and incorrect settings
may damage the appliance. The appliance
manufacturer shall accept no liability for in-
correct connections or incorrect settings.
¡
Wear protective gloves so that you do not
cut yourself. Accessible parts may have
sharp edges.
¡
Do not place the appliance behind a decor-
ative door or the door of a kitchen unit.
There is a risk of overheating.
¡
Never install the appliance in boats or in
vehicles.
¡
Always closely observe the symbols on the
rating plate. If there is no symbol that is rel-
evant to your country, comply with the tech-
nical guidelines in force in your country
when configuring the appliance settings.
¡
Find out which gas type and which gas
pressure your local gas supply network
uses before installing the appliance. Before
using the appliance, ensure that all settings
have been set correctly.
¡
Always comply with local and national
guidelines and regulations.
¡
The settings for configuring your appliance
can be found on the rating plate on the
rear of the appliance. The gas type set at
the factory is marked with an asterisk (*).
¡
After converting the appliance from one
gas type to another, the new gas type must
be labelled on the rating plate.
– Use the gas conversion label to do this.
– (*) is used to indicate the gas type on the label.
– Stick the label on which the gas conversion is
marked with a star (*) in the designated location
on the rating plate.
¡
The changes made to the appliance and
the type of connection are essential to en-
abling the appliance to work safely and in
accordance with the relevant regulations.
¡
Switch off the power supply and gas supply
before carrying out any work.
¡
After working on the gas connection, al-
ways check that the connection is not leak-
ing. The manufacturer accepts no respons-
ibility for a gas leak at a manipulated gas
connection.
WARNING ‒ Risk of explosion!
A gas leak could occur. If you move the appli-
ance after the gas supply has been estab-
lished, a gas leak could occur.
▶
Do not move the appliance once the gas
supply is connected.
▶
If you move the appliance, check that the
connections are not leaking.
ATTENTION!
Do not hold and move the appliance at the
gas pipe (collector). Damage to the gas pipe
may lead to gas leak. The gas pipe is not de-
signed for the weight of the appliance.
▶
Do not hold and move the appliance at the
gas pipe.
18.2 Appliance information
Enter the factory settings for the gas type and gas
pressure in the table below and then add the applic-
able gas type and gas pressure settings for once con-
version has been carried out.
E no.
FD
After-sales service tele-
phone number
Type of gas/gas pressure
The data can be found on
the rating plate.
Type of gas/gas pressure
Data following gas con-
version