1 690 706 220
2016-09-14
|
Robert Bosch GmbH
Technical data | FWA 4650 | 81
en
Fig. 86: Properties of internet protocol Version 4 (TCP/IPv4)
1 Menu item "Use following IP address"
2 "IP address" input field
3 "Sub-net mask" input field
4 "OK" button
!
IP address of the "wireless network link" must be
changed to the valid value.
1. Select the "Use following IP address" item.
2.
Change the IP address in the "IP address" input field
to the valid value to configure/activate the WLAN
network adapter.
Valid network address
Invalid network address
192.168.150.1
192.168.161.1
Tab. 32: Valid/invalid network address
3. Confirm with the "OK" button.
4.
Close the Network link window.
WLAN network link configured.
5.
Re-start the PC/Laptop.
6.
Perform sensor assignment.
i
For sensor position assignment, refer to the
document Commissioning instructions 1690706006.
"
This completes start-up of the WLAN-Box.
11. Technical data
11.1 WLAN-Box dimensions and weights
Function
Unit
Value
Dimensions (L x W x H):
mm
627 x 250 x 131
Dimensions (L x W x H)
with fastening strips:
647 x 250 x 131
Weight
kg
7,4
Degree of protection
(as per DIN 40 050)
IP
54
Tab. 29: WLAN-Box dimensions and weight
11.2 Temperature and working
environment
Function
Unit
Value
Operating temperature
°C
+5 °C - +40 °C
Storage temperature
-20 °C - +60 °C
Temperature gradient
°C / h
20 °C / Stunde
Rel. humidity (operation)
% / °C
10 % - 90 % (40°C)
Rel. humidity gradient
% / h
10 % / Stunde
Max. operating height
m
-200 m - 3000 m
Max. transportation height
-200 m - 12000 m
Tab. 30: Temperature and working environment
11.3 WLAN-Box power supply unit
Function
Unit
Value
Input voltage
V AC (A)
120 / 240 (2,4)
Input frequency
Hz
50 / 60
Power
W
550
Tab. 31: WLAN-Box power supply unit