54 | FWA 4650 | Preparation for installation
en
5.4
Wall installation (suggestion 4)
5.4.1
Fitting
i
WLAN-Box fitting procedure for:
$
4-column lifting platform
$
Scissor lift
$
Pit
2
3
1
4
Fig. 13: Suggestion 4 for fitting WLAN-Box on building wall
1 WLAN-Box
2 Cover for scissor lift hoses and cables
3 Operating unit
4 Building wall
i
When fitting on a 4-column lifting platform or in a
pit, any connecting cables to the WLAN-Box routed
close to the ground must be provided with an
additional cover for protection and to guard against
tripping. When fitting on a scissor lift, use should
also be made of the lift cover.
1. Unfasten the screws (6 x) securing the housing cover
of the WLAN-Box.
i
Refer to Section 5.1.2 Wiring, Fig. 6 for unfastening
the securing screws.
2.
Detach the cover.
1
2
Fig. 14: Removing WLAN-Box fastening strip
1 Securing screws (4 x)
2 Fastening strips (2 x)
3. Remove the securing screws (2 x each) for the
fastening strips (2 x):
4.
Select a position on the wall.