1 690 706 220
2016-09-14
|
Robert Bosch GmbH
52 | FWA 4650 | Preparation for installation
en
16900023_R
e
1
2
3
4
POE
1
2
3
4
Fig. 10: Cable connections in the WLAN-Box
1 LAN cable (2 x) connections 3 + 4, left sensor
2 LAN cable (2 x) connections 1 + 2, right sensor
3 CCD reference system cable connection, left sensor
4 CCD reference system cable connection, right sensor
21.
Attach the connecting cables (6 x).
Cable
Sensors
Component Socket
2 x LAN
3D measurement system
Left
PoE switch
PoE 3 + 4
Right
PoE 1 + 2
1 x
CCD reference system
Left
Connecting
plate
Neutrik left
1 x
CCD reference system
Right
Neutrik
right
Tab. 14: Connections for WLAN-Box connecting cables
!
The LAN cables must be connected to the PoE
sockets of the switch.
22.
Check the position of the WLAN router frequency
switch.
i
The frequency switch is located on the back of the
WLAN router in the WLAN-Box and can be used to
select the frequency of the WLAN link.
!
The WLAN frequency must be 5 GHz.
23.
Re-attach the housing cover.
This completes electrical installation of the
WLAN-Box.
24.
Check the wiring to the sensors.
i
For further information on sensor wiring, refer to
the document Commissioning of FWA 4650
1690706006.
"
This completes electrical installation of the
FWA 4650.
5.2
Installation at cross member of
4-column lifting platform (suggesti
on 2)
5.2.1
Fitting
i
WLAN-Box fitting procedure for front cross member
on 4-column lifting platform. Fitting location:
$
On top of cross member
$
On outside of cross member
$
On inside of cross member
16900027_Re
1
2
3
4
Fig. 11: Suggestion 2 for fitting WLAN-Box on 4-column lifting
platform
1 Front cross member
2 Fitting location on outside of cross member
3 Fitting location on top of cross member
4 Fitting location on inside of cross member
Summary of Contents for FWA 4650