The unit is not
operational after
a firmware
upload.
Power failure during
programming by
firmware file.
Have the unit
checked by Customer
Service and replace if
necessary.
Incorrect firmware
file.
Enter the IP address
of the unit followed
by /main.htmin your
Web browser and
repeat the upload.
Web browser
contains empty
fields.
Active proxy server in
network.
Create a rule in the
local computer's
proxy settings to
exclude local IP
addresses.
Testing the network connection
The ping command can be used to check the connection
between two IP addresses. This allows testing whether a device
is active in the network.
1.
Open the DOS command prompt.
2.
Type
ping
followed by the IP address of the device.
If the device is found, the response appears as "Reply from ... ",
followed by the number of bytes sent and the transmission time
in milliseconds. Otherwise, the device cannot be accessed via
the network. This might be because:
–
The device is not properly connected to the network. Check
the cable connections in this case.
–
The device is not correctly integrated into the network.
Check the IP address, subnet mask, and gateway address.