Standard recording
Select the mode for standard recordings:
–
Continuous
: the recording proceeds continuously. If the maximum recording capacity is
reached, older recordings are overwritten automatically.
–
Pre-alarm
: recording takes place in the pre-alarm time, during the alarm and during the
post-alarm time only.
–
Off
: no automatic recording takes place.
Stream
Select the stream to be used for standard recordings:
–
Stream 1
–
Stream 2
–
I-frames only
Alarm recording
Select a period for the
Pre-alarm time
from the list box. The RAM option allows the pre-alarm
recording ring buffer to be stored in RAM as long as it fits, depending on bit rate settings. This
avoids writing to the SD card or iSCSI. The pre alarm ring is written to storage only on alarm.
Select a period for the
Post-alarm time
from the list box.
Alarm stream
Note
: This function is only available for IR models.
Select the stream to be used for alarm recordings:
–
Stream 1
–
Stream 2
–
I-frames only
Check the
encoding interval and bit rates from profile:
box and select an encoder profile to
set the associated encoding interval for alarm recording.
Alarm triggers
Select the alarm type that is to trigger an alarm recording:
–
Alarm input
–
Analysis alarm
Select the
Virtual alarm
sensors that are to trigger a recording, via RCP+ commands or alarm
scripts, for example.
Export to account
Select an account from the drop-down box to export to an account. If an account has not yet
been defined, click
Configure accounts
to jump to the
Accounts
page where the server
information can be entered.
Copy Settings
You can copy the settings from one profile to another with the
Copy Settings
button. Select
the target profile and click
OK
.
Default
The default values are restored.
Click
Set
to apply the changes.
4.5.3
Maximum Retention Time
Recordings are overwritten when the retention time entered here has expired.
4
Enter the required retention time in days for each recording track.
Once the storage unit is full, the previous recording will be overwritten.
Click
Set
to apply the changes.