6 720 643 259 (2010/05)
Menu settings INSTALLER SETTINGS (for installers only)
|
33
US/CA
8.1.2 INSTALLER SETTINGS: Heating parameters
8.1.3 INSTALLER SETTINGS: Fault history
Menu structure
Heating parameters
Default
setting
Control range
Personal
setting
Description
starts on page
Heating circuit type
Radiators
Baseline/Design temp | Radiant
Floor | Radiators | Baseboard
Base line
78 °F (25 °C)
50 °F ... 186 °F (10 °C ... 85 °C)
°F ( °C)
Design Temp
168 °F (75 °C) 86 °F ... 186 °F (30 °C ... 85 °C)
°F ( °C)
Design supply temp.
168 °F (75 °C) 86 °F ... 186 °F (30 °C ... 85 °C)
°F ( °C)
Maximum heating supply
temperature
176 °F (80 °C) 86 °F ... 186 °F (30 °C ... 85 °C)
°F ( °C)
Room influence
30%
0% ... 100%
%
Room influence enabled for
modes
Eco/Frost
Eco/Frost | Comfort/Eco/Frost
Room temperature offset
0 °F (0.0 °C)
– 9 °F ... 9 °F
( – 5.0 °C ... 5.0 °C)
°F ( °C)
Heating OFF until lower level
reached
Yes
No | Yes
Heating OFF at outdoor
temperature
68 °F
(20.0 °C)
50 °F ... 77 °F
(10.0 °C ... 25.0 °C), 210 °F
(99.0 °C) (= function off)
°F ( °C)
Risk of freezing at outdoor
temperature
38 °F (3.0 °C) 23 °F ... 50 °F
( – 5.0 °C ... 10.0 °C)
°F ( °C)
Mixer run time
140 s
10 s ... 600 s
s
Minimum outdoor temperature
5 °F ( – 15 °C) – 22 °F ... 32 °F
( – 30 °C ... 0 °C)
°F ( °C)
Building storage capacity
50%
0% ... 100%
%
Calibrate internal room temp
sensor
0.0 °F (0.0 °C) – 5.4 °F ... 5.4 °F
( – 3.0 °C ... 3.0 °C)
°F ( °C)
Heating circuit solar
optimization
1)
0 °F (0 °C)
0 °F (= function off) ... 9 °F
(0 °C ... 5 °C)
°F ( °C)
1) Only with ISM
Menu structure
Fault history
Default
setting
Control range
Personal
setting
Description
starts
on page
01/01/2010
04:11pm
EA Boiler
(example for last fault)
– –
–
09/25/2010
06:45pm
32 IPM ID 10
(up to maximum of 19 past
faults)
– –
–