DS940P/DS940PT
Passive Infrared Detector
With Pet Immunity
Installation Instructions
1.0
Description
The DS940P is a high performance Passive Infrared (PIR) Motion Sensor which uses advanced signal processing to provide outstanding
catch performance and unsurpassed false alarm immunity. It is designed to detect movement in the interior of a structure by sensing the
Infrared energy emitted from the human body as it moves across the sensor’s field of view. When motion is detected the unit sends an alarm
signal to the Control Panel. With Bosch Security Systems Pet Friendly
®
pet immunity, the DS940P will not detect a dog up to 30 pounds (13
kilos), two cats, or numerous rodents. This pet immunity feature has not been tested by Underwriters Laboratories.
2.0
Specifications
• Input Power:
9-15 volts DC
• Current Draw:
17 mA @ 12 VDC (standby and maximum)
• Standby Power: No internal standby battery. For UL Listed Prod-
uct Installations, 4 hours (68 mAh) standby pow-
er must be provided.
• Relay
Form “A” Normally Closed (NC) contact set rated
for 125 mA@ 28 volts maximum DC, 18 volts
maximum AC for resistive loads.
• Tamper:
(DS940PT only) Normally Closed (with cover on).
Contacts rated at 28 VDC, 125mA max. Connect
tamper circuit to a 24hr. protection circuit.
• Temperature:
-20° to +120°F (-29° to +49°C). For UL Listed
Product Installations, the temperature range is
+32° to +120°F (0° to +49°C).
• Humidity:
0 - 85% non-condensing.
• Dimensions:
3 in. H x 2.25 in. W x 1.5 in. D
(7.6 cm x 5.7 cm x 3.8 cm)
• Options:
B335 Swivel Mounting Bracket. Use of this bracket
may decrease the PIR range and increase dead
zones.
•
Reading Bosch Security Systems, Inc. Product Date Codes
For Product Date Code information, refer to the Bosch Security
Systems, Inc. Web site at:
http://www.boschsecurity.com/
datecodes/
3.2
Press the vertical adjust tab
toward the side of the case and
lift out the board.
3.4
Avoid.
3.0
Installation
3.1
Remove the cover
using
a small flat-blade
screwdriver.
3.3
Select a mounting location.
Mount the sensor where an
intruder will most likely cross
through the coverage pattern.
3.5
Observe the pet immunity mounting recommendations.
Bottom of Detector
Insert screwdriver here or here
Pet
Immune
Area
NO
OK
LED
ON
7.5-9ft
Don't point where pets can climb
NO
Note: The upper areas are not
pet immune.
7.5 - 9 ft.
(2.25 - 2.7 m)
Mount the detector 7.5 - 9 feet
(2.25 - 2.7 meters) above the floor
Moving Objects
Heat
Sources
Windows
and
Uninsulated
Walls
Air
Conditioning
Outlets
Direct Hot or
Cold
Drafts
Mounting
Outdoors
Direct Sunlight