DIVAR IP all-in-one 7000 (2U)
Maintenance | en
45
Bosch Security Systems B.V.
Installation manual
2019.08 | V1 | DOC
The power supply can be replaced without turning off the system if a redundant power supply
is available.
Replacement units can be ordered directly from Bosch RMA desk.
To replace the power supply:
1.
Unplug the AC power cord of the failed power supply.
2.
Push the release tab on the back of the power supply.
3.
Pull the power supply out using the handle provided.
4.
Replace the failed power supply with the same model.
5.
Push the new power supply into the power bay until you hear a click.
6.
Plug the AC power cord back into the power supply and turn on the unit.
9.15
Replacing the power distributor
Redundant chassis that are 2U or greater require a power distributor. The power distributor
provides failover and power supply redundancy.
To replace the power distributor:
1.
Turn off the unit and remove the plug from the wall socket or power strip.