44
en | Configuration
FLEXIDOME IP 3000i IR | FLEXIDOME IP micro
3000i | DINION IP 3000i IR | FLEXIDOME IP turret
3000i IR
2020-01 | V02 | DOC
User manual
Bosch Security Systems B.V.
Attach JPEG from camera
To send a JPEG image from a particular video channel, check the appropriate box.
VCA overlays
Select the
VCA overlays
check box, to place the outline of the object that triggered an alarm
into the camera image sent as snapshot via e-mail.
Destination address
Enter the e‑mail address for alarm e‑mails here. The maximum address length is 49 characters.
Sender address
Enter a unique name for the e‑mail sender, for example, the location of the device. This makes
it easier to identify the origin of the e‑mail.
Test e-mail
Click
Send Now
to test the e‑mail function. An alarm e-mail is immediately created and sent.
Click
Set
to apply the changes.
4.5.5
Alarm Task Editor
Editing scripts on this page overwrites all settings and entries on the other alarm pages. This
procedure cannot be reversed.
To edit this page, you should have programming knowledge and be familiar with the
information in the Alarm Task Script Language document and the English language.
As an alternative to the alarm settings on the various alarm pages, enter the desired alarm
functions in script form here. This will overwrite all settings and entries on the other alarm
pages.
1.
Click
Examples
under the Alarm Task Editor field to see some script examples. A new
window opens.
2.
Enter new scripts in the Alarm Task Editor field or change existing scripts in line with your
requirements.
3.
When finished, click
Set
to transmit the scripts to the device. If the transfer was
successful, the message
Script successfully parsed.
is displayed over the text field. If it
was not successful, an error message is displayed with further information.
4.6
Interfaces
4.6.1
Alarm Inputs
Active
Configure the alarm triggers for the unit.
Select
N.C.
(Normally Closed) if the alarm is to be triggered by opening the contact.
Select
N.O.
(Normally Open) if the alarm is to be triggered by closing the contact.
Select
N.C.S.
(Normally Closed Supervised) if the alarm is to be triggered by opening the
contact.
Select
N.O.S.
(Normally Open Supervised) if the alarm is to be triggered by closing the
contact.
A supervised alarm transmits both the alarm condition and the tamper condition. Depending
on how the alarm is configured, a short or a break in the alarm’s circuit can trigger the tamper
signal.
Name
Enter a name for the alarm input. This is then displayed below the icon for the alarm input on
the
Live
page (if configured).