Bosch D222TD Installation Instructions Manual Download Page 1

D222TD

EN

Installation Instructions

Keypad

Summary of Contents for D222TD

Page 1: ...D222TD EN Installation Instructions Keypad ...

Page 2: ...ram text remotely using the D5300 Remote Account Manager II RAM II or Remote Programming Software RPS 1 1 Display The D222TD continuously displays the latest status conditions of the security system Once the program is received it takes 15 seconds for the new text to replace the old text When a series of events affecting the system occurs the D222TD displays each event by priority For example alar...

Page 3: ... 1 Select a mounting location Do not place the D222TD Keypad in areas of extreme cold such as uninsulated buildings refrigerated areas outdoors or areas where the temperature can drop below 0 C 32 F Do not mount the D222TD in locations exposed to direct sunlight Direct sunlight makes the display less visible and can damage the keypad s components Mount the D222TD on a flat wall or on the following...

Page 4: ... to the wires Connect the three wire cable to the control panel and the six wire cable to the expanded points 1 Protective point wiring connector J2 4 Display adjustment potentiometer R50 2 Data wire connector J1 5 S1 DIP switch 3 Wire opening Figure 3 Inside the D222TD 4 2 3 4 5 6 7 8 9 0 A B C 1 CLEAR 2 1 3 5 ON Insulate all exposed splices with tape so they do not short to one another 6 Remove ...

Page 5: ...tom text preserve the custom text by a Copying the control panel s program using a D5200 b Attaching a new D222TD at Address 1 c Reprogramming the control panel using the copied program 11 Disable the sounder Set DIP Switch 3 to the OFF position see Figure 4 The fire points need the trouble sounder Disabling the sounder with DIP Switch 3 stops the D222TD from annunciating fire point trouble If thi...

Page 6: ...closure Dimensions H x L x D 12 cm x 21 cm x 2 cm 4 56 in x 8 15 in x 816 in Color Off white Operating Temperature 0 C to 50 C 32 F to 122 F Non condensing Relative Humidity 5 to 85 at 30 C 86 F Keypad Wiring Three wire cable supplies data in common and positive voltage Point Wiring Four two wire loops Each loop uses a 1 kΩ EOL resistor for point supervision Compatible with sensing devices with NO...

Page 7: ...EN 7 D222TD Installation Instructions Bosch Security Systems 12 03 74 07391 000 B Notes ...

Page 8: ...Bosch Security Systems 130 Perinton Parkway Fairport NY 14450 9199 USA www boschsecurity us Customer Service 800 289 0096 Technical Support 888 886 6189 2003 Bosch Security Systems 74 07391 000 B ...

Reviews: