Installation and Manual Documentation
Document date:
CC-DA/ESR1
CR5CPCCF
18 Feb 2020
Page:
23
© All rights reserved, Robert Bosch GmbH, also for the case of protected rights applications every power of disposal, like copy-right
and passing on rights, with us. The valid issue of this template is filed in CC-DA process landscape.
a
eff
= 30.8 m/s²
Protection class:
According to International Protection Marking, ISO 20653
IP6Kx, IPx6K, IPx7, IPx9K
Temperature range with restricted operation (communication interface working):
T85°C ... Tmax=+95°C.
Temperature range of operation:
Top_min= -40°C ... T85°C.
Duration see Reliability
Corrosion resistance against salt spray and humidity
According to DIN EN 60068-2-11
Sensor may not be exposed to direct UV light for more than 48h
3.2.
Electrical characteristics
The chapter electrical car integration describes the vehicle connector interface of the Radar SCU.
The detailed description of the following connection topics are adapted to the defined feature
configuration:
- Connector Pinning
- Connector Power Supply Interface
- Connector Communication Interface
- Connector Multi-Purpose I/O Interface