11.3.6 EVU/SG wiring diagram for the indoor unit with an
integrated electric booster heater
11.3.7 Photovoltaic
Since there are only two external inputs for the energy supplier and PV,
these cannot be used at the same time.
PV connection to external input 1 or 4.
The heat pump is able to process a control signal of a PV system.
If the PV system has sufficient current for operating the heat pump, it can
communicate this information to the heat pump in the form of a start
command via a control cable. The control cable must be connected to
one of the available external connections. The selected external
connection must be configured in the control unit for the PV function.
The heating system must have a buffer cylinder and only heating circuits
with a mixer in order for a start command to be effective. A start
command causes the buffer cylinder to be charged up to the maximum
temperature achievable by the heat pump. However, it can only be
charged when the temperature in the buffer cylinder is below the
maximum temperature. Otherwise, the heat pump remains off.
11.4
Kabelplan
Table 11 Connections in indoor units IDU AWE/AWM/AWMS and AWB
Table 12 Cable plan sensor
11.5
Measurements from temperature sensors
Designation
min. cross-
section
type of cabel
max. length
connected at:
connection
terminal:
Power source
3-way valve
VW1
3 x 1,5mm²
cable integrated
Indoor unit
53 / 54 / N
IDU
Pump 1. HC
PC1
3 x 1,5mm²
H05VVF
Indoor unit
52 / N / PE
DHW pump
PW2
3 x 1,5mm²
H05VVF
58 / N / PE
Signal cable IDU - ODU
CAN-BUS
2 x 2 x 0,75mm
2
LIYCY (TP)
30m
Can High 31(H)
Can Low 32(L)
12V not
connected
2-wire
connection,
shielding in both
ends
Power supply
IDU AWE/
AWM/AWMS
5 x 2,5mm²
NYY
Indoor unit
sub-distribution
3 x C16
Power supply
IDU AWB
3 x 1,5mm²
NYY
Indoor unit
L / N / PE
sub-distribution
1x C16
Heating cable
3 x 1,5mm²
NYY
3m
Indoor unit
56 / N / (HC /
HC)
IDU / HC / HC
EMS - Module
MM100,
MS100..
0,5mm²
J-Y (ST)Y 2 x 2 x 0,6
100m
Indoor unit
19 / 20
0-10V control boiler
EM0
2 x 2 x 0,75mm
2
LIYCY (TP)
Indoor unit
(IDU AWB)
38 / 39
PV-Function
0,4mm²
J-Y (ST)Y 2 x 2 x 0,6
From inverter on terminal I1 or I4 in IDU,
EVU-block or Smart Grid
Smart Grid
0,4mm²
J-Y (ST)Y 2 x 2 x 0,6
From load management controller on terminal I4,
connection 49, 50 in IDU
EVU-block
3 x 1,5mm²
H05VVF
From load management controller on terminal I1,
connection 13, 14 in IDU
Sensor
Designation
min. cross-
section
type of cabel
max.
length
connected at:
connection
terminal:
Power source
Outdoor
T1
0,5 mm
2
J-Y (ST)Y 2 x 2 x 0,6
Indoor unit
3 / 4
Flow
T0
0,5 mm
2
J-Y (ST)Y 2 x 2 x 0,6
Indoor unit
1 / 2
Hot water (DHW)
TW1
0,5 mm
2
J-Y (ST)Y 2 x 2 x 0,6
Indoor unit
5 / 6
Dew sensor
MK2 (max. 5x)
0,5 mm
2
cable integrated
Indoor unit
34 / 35
Mixed heating circuit
TC1
0,5 mm
2
J-Y (ST)Y 2 x 2 x 0,6
100m
MM100
1 / 2
Pool temperature
TC1
0,5 mm
2
J-Y (ST)Y 2 x 2 x 0,6
100m
MP100
1 / 2