3-2
Climate Class 6100i / 6000i / 8100i / 8000i
• Full power setting
• Self cleaning
• Multi Space setting
• ECO setting
3) Disabling auto restart function
By removing (cutting) jumper (JP0) on the printed circuit board(PCB), the auto restart function can be disabled.
12. Save operation
This control is valid only in AUTO mode.
In addition, Average models (CLC6001i-W 25/35 E, CLC8001i-W 25/35 E(T/S/R)) only when ECO mode is enabled. Nordic models (CLC6101i-W
50/65 HE, CLC8101i-W 65 HE(T/S/R)) only when another mode is disabled.
If there is no person for 1 hour, the air conditioner will arise setting temperature.
If a person is detected, correction temperature will be restored.
13. Activity Detection
This control is valid only in AUTO mode. If the amount of human activity increases for few minutes, setting temperature is lowered, fan rotation is
increased by 100rpm when fan setting is AUTO, and horizontal louver (H-louver) is turned downward when the louver setting is AUTO. If a person’s
activity decreases, it is returned to original state.
Setting temperature is corrected lower by the amount of human activity as following.
temperature correction table temperature correction degree
activity weak activity mid
activity strong
room
temperature(°C)
29/30
1
1.75
2.5
27/28
1
1.5
2
25/26
0.5
1
1.5
23/24
0.25
0.75
1.25
17~22
0.25
0.5
0.75
16
0
0
0
Summary of Contents for CLC6001i 25 E
Page 69: ...2 Climate Class 6100i 6000i 8100i 8000i 6 1 6 3 6 4 6 2 ...
Page 77: ...10 Climate Class 6100i 6000i 8100i 8000i 6 1 6 3 6 4 6 2 ...
Page 87: ...20 Climate Class 6100i 6000i 8100i 8000i 7 28 Reverse Value Ass y ...
Page 88: ...21 Climate Class 6100i 6000i 8100i 8000i Expansion Value Ass y ...