13.3 Online calibration of multipoint adjustment
channels
Example: measurement of wheel force
– Physical property ‘wheel force’ not directly measureable
– Load transfer through suspension kinematics
– Physical value at sensor position defined by vehicle
– Curve definition by online adjustment at vehicle
Force at wheel
Force at sensor
1.
Create a multipoint adjustment measurement channel. To create a multipoint channel,
see chapter ‘Configuring a multipoint adjustment [
64]’.
2.
Download the configuration on the C 80. To connect the C 80 to RaceCon, see
chapter ‘Setting up a new RaceCon Project [
15]’.
3.
Click on the desired channel in the C 80 Project Tree.
4.
Double-click on a measurement channel in the Data Area to open the online view.
Click to open
measurement
channels in data
view
Double-click
to open
online view
Click to open
calibration
window
Analog and physical
value
5.
Click on ‘Calibrate adjustment points’ to open calibration window.
6.
Apply the desired physical condition to the sensor (e.g. by applying a force on the
wheel).
7.
Enter the physical value in the value column of the desired calibration point
(e.g. 745 N).
Summary of Contents for C 80
Page 1: ...Data Logger and Sensor Interface C 80 Manual Version 1 0 04 08 2021 ...
Page 11: ...Mechanical Drawing 5 Bosch Motorsport Manual_C_80 11 144 5 Mechanical Drawing ...
Page 30: ...8 First Steps 30 144 Manual_C_80 Bosch Motorsport ...
Page 141: ...Bosch Motorsport Manual_C_80 141 144 ...
Page 142: ...142 144 Manual_C_80 Bosch Motorsport ...
Page 143: ...Bosch Motorsport Manual_C_80 143 144 ...
Page 144: ...Bosch Engineering GmbH Motorsport Robert Bosch Allee 1 74232 Abstatt www bosch motorsport com ...