1 691 606 210
2015-07-29
|
Robert Bosch GmbH
Manual mode (normal operation) | BSA 43xx | 55
en
5.2.4
Noise simulator SDL 435
i
The noise simulator can only be used in manual mode.
Step
Remote control unit
Result / Display
1.
Check prerequisites:
R
No vehicle on dynamometer!
R
Tester/test routine selected.
Left: "Noise simulator" device symbol.
Right: Drive-on prompt.
2.
Drive onto the suspension tester with
the axle to be measured first and
keeping the vehicle
straight
. Press the
brake
to stop the vehicle moving.
Axle to be measured is positioned in noise
simulator.
Screen displays axle load (kg).
Ready for noise measurement.
3.
Select measurement mode:
R
Left single wheel measurement.
R
Right single wheel measurement.
Left single wheel
Right single wheel
Announcement phase:
Message line flashes to indicate starting of
motor.
i
The measurement can be terminated at any
time with the
STOP
button.
4.
Motor of selected shaker plate starts
up.
i
The motor runs until the maximum
test time is completed (standard value
180 seconds).
Vehicle is caused to oscillate.
Screen indicates active shaker plate.