Bosch BML 2410 Repair Instructions Download Page 1

1

Instandsetzunganweisung

Repair Instructions

BML 2410 / BML 2410 FW / BML 2415 / BML 2415 FW

Batterie Ladegeräte für 12 V / 24 V Batterien
Battery chargers for 12 V / 24 V batteries

Summary of Contents for BML 2410

Page 1: ...1 Instandsetzunganweisung Repair Instructions BML 2410 BML 2410 FW BML 2415 BML 2415 FW Batterie Ladegeräte für 12 V 24 V Batterien Battery chargers for 12 V 24 V batteries ...

Page 2: ...n 4 Contents Page 1 Important Information 5 1 1 Test Apparatus and Tools 5 2 Testing and Trouble Shooting 5 2 1 Testing the Current Consumption at No Load 5 2 2 Testing the Charging Current 6 2 3 Testing the Reverse Battery Protection 6 2 4 Testing the Secondary Voltage 12V 24V 6 3 Verdrahtungsplan Circuit Diagram 7 3 1 BML 2410 BML 2410 FW 7 3 2 BML 2415 BML 2415 FW 8 4 Explosionszeichnung Explod...

Page 3: ...tsprechenden Sicherheitsvorschriften 2 Prüfung und Fehlersuche Achten Sie bei den Prüfungen auf Wackelkontakte verschmutzte und korrodierte Steckkontakte sowie auf Knick und Quetsch stellen der Leitungen 2 1 Stromaufnahme im Leerlauf prüfen Achten Sie darauf dass das Ladegerät vor dem Öffnen an keiner Spannungsquelle angeschlossen ist Öffnen Sie das Ladegerät Trennen Sie den Stecker X6 der Netzans...

Page 4: ...zu vermeiden stellen Sie die Ausgangsspan nung des Trenntransformators auf 0V Schließen Sie das Ladegerät an den einstellbaren Trenntrans formator an Schließen Sie die schwarze Anschlussklemme an den Pluspol der Batterie an Schließen Sie die rote Anschlussklemme über ein Ampereme ter z B MMD 302 am Minuspol der Batterie an Schalten Sie das Ladegerät ein Erhöhen Sie die Spannung am Trenntransformat...

Page 5: ...driver for torx socket bolts TX 10 Tester in accordance with DIN VDE 0702 0701 Part 1 or in accordance with the applicable safety regulations of the parti cular country 2 Testing and Trouble Shooting When testing check for loose connections dirty and corroded plug connections and bent or crushed cables 2 1 Testing the Current Consumption at No Load Ensure that the charger is disconnected from all ...

Page 6: ...su ring instrument set the output voltage of the isolating trans former to 0V Connect the charger to the adjustable isolating transformer Connect the black terminal to the positive terminal of the battery Connect the red terminal to the negative terminal of the battery via an ammeter e g MMD 302 Switch on the charger Slowly increase the voltage at the isolating transformer until it reaches 230V or...

Page 7: ...7 3 Verdrahtungsplan Circuit Diagram 3 1 BML 2410 BML 2410 FW 1A 2A 3A 4a 5a 6a 1A 2A 3A 4a 5a 6a T2 T1 3 T1 6 T1 15 T1 18 T1 14 T1 16 T1 12 T1 10 ye gn rd 3 15AT 4510008 1Lt P1 S1 V1 S2 F1 B4 A1 ...

Page 8: ...6 T1 12 T1 10 ye gn rd 3 15AT 4510008 1Pal P1 S1 V1 S2 F1 B4 A1 3 2 BML 2415 2415FW Anschlusshinweis für Ampermeter V1 1 687 235 294 Terminal diagramm for ammeter V1 1 687 235 294 4510008 5Pal oder or Vorderseite Frontside Rückseite Backside COKA CK 550 JUMBOSOLENOID JB 550 ...

Page 9: ...9 4510008 2Lt BOSCH A 24V 12V BML 241 DC AMPERES 0 5 10 15 4 Explosionszeichnung Exploded View ...

Page 10: ...10 ...

Page 11: ...nzugefügt 3 Kapitel 2 4 Sekundärsapnnung für BML 2415FW hinzugefügt 4 Kapitel 3 2 Verdrahtungsplan angepasst und Anschlusshin weis für Ampermeter V1 Jumbosolenoid erweitert 11 07 2003 Pal 1 Kapitel 3 2 neu hinzugefügt Mit Anschlusshinweis des Amper meters V1 27 03 2001 Instandsetzungsanleitung neu erstellt ...

Page 12: ...9 BML 2415FW 0 687 000 010 1 689 975 162 WIF 1007 1 DeEn 28 01 2004 Printed in Germany Imprimé en Allemagne Robert Bosch GmbH Geschäftsbereich KH Produktbereich Prüftechnik Postfach 1129 D 73201 Plochingen www bosch de prueftechnik e Mail Bosch Prueftechnik de bosch com ...