1 689 989 131
2019-03-02
|
Robert Bosch GmbH
| BAT 131 | 29
en
7. Decommissioning
8. Technical data
Function / Range
Value
Function range
0 °C – 50 °C
32 °F – 122 °F
Accuracy range
0 °C – 40 °C
32 °F – 104 °F
Workplace-related
noise-emission value (Lpa)
< 70 dB(A)
8.1
Battery-Test and Voltmeter
Function / Range
Value
Operating voltage
1 V – 30 V
Operating current without printer
0,4 A
Entry range of Cold Start Current
50 A - 1550 A
Battery standards
DIN, EN, EN2
IEC, JIS, SAE
8.2
Printer Paper
Function / Range
Value
Maximum storage period by storage in
the dark in years
< 5
Maximum storage temperature
30 °C
32 °F – 86 °F
Maximum storage humidity
<60 %
BAT 131, accessories and packaging should
be sorted for environmental-friendly recycling.
¶
Do not dispose BAT 131 into household waste.
Only for EC countries:
The BAT 131 is subject to the European
directive 2012/19/EC (WEEE).
Dispose of used electrical and electronic
devices, including cables, accessories and
batteries, separately from household waste.
¶
Make use of the local return and collection
systems for disposal.
¶
Proper disposal of BAT 131 prevents
environmental pollution and possible health
hazards.
6.7
Troubleshooting the Printer
!
If the BAT 131 is not connected to a 12-volt battery
with at least 11.5 volts of power or the paper sensor
does not detect paper in the compartment during the
print process
Message
Action to be taken
BATTERY POWER TOO
LOW TO USE PRINTER.
CONNECT TO FULLY
CHARGED BATTERY
11.50 TO 16.00V
To print, the tester must be properly
connected to a vehicle battery
having at least 9 volts.
R
Connect to a vehicle battery with
enough voltage to enable printing.
R
Make sure that the clamps are
connected properly: red clamp to
the positive (+) terminal and the
black clamp to the negative (-)
terminal.
R
Check that both sides of the
clamps are making contact with
the terminals.
CONNECT TO
12V BATTERY
Tester is not connected to the
battery
LOW INTERNAL AA
BATTERIES. REPLACE AA
BATTERIES SOON!
Internal AA batteries are low
and need to be replaced. See
"Maintenance & Troubleshooting"
section.
NON 12 VOLT SYSTEM
DETECTED
System being tested is not 12-volts.
PRINTER DOOR OPEN.
CLOSE DOOR AND TRY
TO PRINT AGAIN
Check that the door covering the
printer paper is properly closed and
latched.
PRINTER OUT OF PAPER
REPLACE WITH THERMAL
PRINTER PAPER.
2.5 IN. DIA. MAX
2.25 IN. WIDE MAX
Printer is out of thermal paper.
R
Verify that the paper is inserted
correctly.
R
Insert a new roll of paper.
R
Verify that the paper sensor is
clean and undamaged
QC DATA MEMORY FULL
PRINT RESULTS OR
CLEAR MEMORY.
QC mode memory is full. Select QC
mode from the Options Menu to
clear the memory.