26.3 Test
Use the Test menu to walk test your system, send test reports, or
to review system revision information on the keypad display.
26.3.1 Walk Test
A walk test allows you to test the sensors, keypads, sounders,
and other devices in your system without creating alarm events.
You can review untested points at the keypad to help pinpoint
any problems.
You cannot turn on the security system while in the walk test
mode. Also, the security system does not create alarm events for
points included in the walk test. Points not included create alarm
events. For example, faulting a fire point during an intrusion walk
test creates a fire alarm event.
Beginning the walk test activates the burglary tone for 2 seconds.
A battery test also begins. A successful battery test ends in four
minutes (the walk test continues). If the security system
determines there is a low battery, it generates a low battery
event and continues the test. If the battery is determined to be
very low, the system creates a missing battery event and ends
the battery test immediately.
To test individual detection devices, simply activate sensors and
open protected doors and windows one-at-a-time. As you fault
each detection device, the keypad from which you initiated the
Control Panels