For each relay, you can specify an open switch relay (normally closed contact) or a closed
switch relay (normally open contact).
You can also specify whether an output should operate as a bistable or monostable relay. In
bistable mode, the triggered state of the relay is maintained. In monostable mode, you can set
the time after which the relay will return to the idle state. You can select different events that
automatically activate an output. It is possible, for example, to turn on a floodlight by
triggering a motion alarm and then turning the light off again when the alarm has stopped.
Idle State
Select Open if you want the relay to operate as an NO contact, or select Closed if the relay is
to operate as an NC contact.
Operations Mode
Select an operating mode for the relay.
For example, if you want an alarm-activated lamp to stay on after the alarm ends, select
Bistable. If you wish an alarm-activated siren to sound for ten seconds, for example, select
10s.
Relay Name
You can assign a name for the relay here. The name is shown on the button next to Trigger
relay. The Livepage can also be configured to display the name under the relay icon.
Furthermore, in the Forensic Search program, you can use the name as a filter option for quick
search through the recordings.
!
Caution!
Do not use any special characters, for example &, in the name.
Special characters are not supported by the system's internal recording management and may
therefore result in the Player and Archive Player programs being unable to play back the
recording.
Trigger Relay
Click the button to trigger the relay manually (for testing or to operate a door opener, for
example).
Advanced Mode: Network
Network Access
The settings on this page are used to integrate the camera into an existing network.
Some changes only take effect after the unit is rebooted. In this case, the Set button changes
to Set and Reboot.
1.
Make the desired changes.
2.
Click the Set and Reboot button. The camera reboots and the changed settings are
activated.
!
Caution!
If you change the IP address, subnet mask or gateway address, the camera is only available
under the new addresses after the reboot.
Automatic IP assignment
If a DHCP server is employed in the network for the dynamic assignment of IP addresses, you
can activate acceptance of IP addresses automatically assigned to the camera.
12.48
12.49
AutoDome Junior HD Series
Configuring the AutoDome Junior HD | en
93
Bosch Security Systems, Inc.
Operation Manual
2014.11 | 6.1 | F.01U.275.803
Summary of Contents for AutoDome Junior HD VJR Series
Page 1: ...AutoDome Junior HD Series VJR Series en Operation Manual ...
Page 2: ......
Page 112: ......
Page 113: ......